Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 4-hour, 100% full load aging and full-series functional testing. |
|||
|
Features |
SDBD-010-1H |
SDBD-010-1G |
SDBD-010-1B |
|
Rated Output Voltage |
DC12V |
DC5V |
DC24V |
|
Output Interface Location |
The two 5mm-M4 connectors are labeled OUTPUT: DC+; DC-. |
||
|
Output Voltage Range |
Setting error: <±2%; Adjustable range: ±10% |
||
|
Rated Output Current |
Rated value 1A, operating current range 0~1A |
Rated value 2A, operating current range 0~2A |
Rated value 0.5A, operating current range 0~0.5A |
|
Output Voltage Ripple |
Vnor<50mV;Vp-p100Hz<100mV;Vp-pmax<120mV |
Vnor<20mV;Vp-p100Hz< 50mV;Vp-pmax<100mV |
Vnor<100mV;Vp-p100Hz<150mV;Vp-pmax<200mV |
|
Li;Lo Regulation |
Line:±0.5%;Load:±0.5% |
||
|
Overall Voltage Regulation Accuracy |
±1% |
||
|
Rated Output Power |
10W |
||
|
Rated Operating Efficiency |
≥80% (output power is rated) |
||
|
Rated Input Voltage |
Rated voltage: AC100-240V, operating voltage: AC90-264V. Interface: Three-position 5mm-M4 connector, labeled INPUT: AC-L, AC-N, FG. |
||
|
Rated Input Current |
Rated current: AC220V: AC0.065A, current range AC0.01A~0.045A |
||
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
||
|
Inrush Current |
The surge current to the power grid at the moment of power-on: the maximum value during cold start is 20A/10ms. |
||
|
Input Overvoltage Protection |
Input allowable range: AC0~280V; Overvoltage protection point: AC300V±5V, power supply enters irreversible shutdown state. |
||
|
Output Overload Protection |
The overload protection point is approximately 110% of the rated output current, and the protection is a current-limiting and voltage-reducing method; the short-circuit protection is an online voltage-drop shutdown method, and the input needs to be reset to restore it. |
||
|
Overheat protection |
The overheat protection point is 85℃±5℃, and the protection method is online shutdown. Normal operation resumes when the overall machine temperature drops below 50℃±3℃. |
||
|
Multi-unit series/parallel operation |
Multiple power supplies of the same series are allowed to be used in series and parallel (parallel operation with uneven current distribution). |
||
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
||
|
Isolation voltage parameters |
[Input-Output: AC1.5KV, Input-Casing: AC1.5KV, Output-Casing: AC0.5KV] 50Hz, Power-on for 1 minute: Leakage current <8mA |
||
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.05 [%/℃]; the absolute temperature rise coefficient is approximately 0.2 [℃/W]; when the operating output is at rated power, the absolute temperature rise of the machine body is 25℃±5℃. |
||
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: 0℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
||
|
Cooling method |
Designed for continuous operation with natural cooling (power consumption is affected by the operating environment and installation location). |
||
|
External dimensions and mounting dimensions |
Specifications: L70×W39×H30mm3; Maximum size: L70×W39×H30mm3; |
||
|
Net weight and color |
The total weight is approximately 100g; the bottom shell is made of 1.5mm thick iron with a polished and anodized black finish; the top shell is made of 0.6mm thick iron with a nickel-plated black finish. |
||
|
Design standards |
National Standards GB-4943 and GB-9254 |
||
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the 100Hz main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
|||
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen