Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 4-hour, 100% full load aging and full range of functional tests. |
||||||
|
Features |
SFLD-030-2L |
SFLD-030-2A |
SFLD-030-2G |
SFLD-030-2R01 |
SFLD-030-2K |
|
|
Rated Output Voltage |
DC +12V -12V |
DC +12V 5V |
DC +5V 12V |
DC+15 -15V |
DC +24V 5V |
|
|
Output Interface Location |
The black P=8.5 six-pin connector is labeled DC1, COM, DC2, etc. |
|||||
|
Output Voltage Range |
Setting error: ±0.5V; Adjustable range: ±10% |
Setting error: ±0.5V; |
||||
|
Rated Output Current |
2A 1A |
2.5A 1.5A |
3A 1.5A |
1.5A 1A |
1A 1A |
|
|
Output Voltage Ripple |
Vp-p100Hz<50mV;Vp-pmax<150 mV |
Vp-p100Hz<50mV;Vp-pmax<200 mV |
||||
|
Li;Lo Regulation |
Line:±0.5%;Load:±0.5% |
Line:±1%;Load:±5% |
||||
|
Overall Voltage Regulation Accuracy |
±3% |
±10% |
||||
|
Rated Output Power |
30W |
|||||
|
Rated Operating Efficiency |
≈80% (output power is rated, AC220V) |
|||||
|
Rated Input Voltage |
Input range: AC100~240V; Rated voltage: AC220V. Interface position: Three-position covered socket labeled AC-L, AC-N, FG (with wire). |
|||||
|
Rated Input Current |
Rated current: AC 0.4A (AC 220V), current range AC 0.3~0.5A |
|||||
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|||||
|
Inrush Current |
The inrush current to the power grid at the moment of power-on: the maximum value during cold start is 20A/10ms. |
|||||
|
Input Overvoltage Protection |
Input allowable range: AC0~280V; Overvoltage protection point: AC300V±5V, power supply enters irreversible shutdown state. |
|||||
|
Output Overload Protection |
The overload protection point is approximately 110%~150% of the rated output power; the overload protection is an online power limiting and voltage reduction method. |
|||||
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|||||
|
Dielectric strength parameters |
[Input-Output: AC1.5KV; Input-Casing: AC1.5KV] Leakage current <5mA 50Hz 1min. |
|||||
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.03 [%/℃]; the absolute temperature rise coefficient is approximately 0.50 [℃/W]; the absolute temperature rise of the chassis when operating at rated power is 30℃±5℃. |
|||||
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|||||
|
Cooling method |
Designed for continuous operation, with self-cooling and heat dissipation assistance. (Power consumption and lifespan are affected by differences in the usage environment and installation location.) |
|||||
|
External dimensions and mounting dimensions |
Specifications: L88×W70×H38mm³; Maximum size: L88×W85×H38mm³; Installation dimensions: Bottom L78×W74mm², Side L78×W0mm² |
|||||
|
Net weight and color |
Total weight 200g; bottom shell is 1.5mm thick aluminum with a white sandblasted finish; top shell is 0.7mm thick iron with a white finish. |
|||||
|
Certification Security Specifications |
National Standards GB-4943 and GB-9254 |
|||||
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
||||||
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen