FP type 60W series

  • Detailed Description

Detailed explanation:

• Compact size and lightweight.

• High reliability and low price.

• Wide input voltage range.

• High conversion efficiency and low operating temperature rise.

• Built-in filter circuit, minimizing external radiated interference.

• Basic protection circuitry, providing good environmental adaptability.

• 4-hour, 100% full load aging and full-series functional testing.

Features
Model
Parameters

SFPD-

060-1E

SFPD-

060-1G

SFPD-

060-1F

SFPD-

060-1A

SFPD-

060-1H

SFPD-

060-1K

SFPD-

060-1I

SFPD-

060-1B

SFPD-

060-1J

SFPD-

060-1C

 

Rated Output Voltage

DC 3.3V

DC 5V

DC 7.5V

DC 10V

DC 12V

DC 15V

DC 18V

DC 24V

DC 36V

DC 48V

Output Interface Location

The five-pin 5.0-M4 connector is labeled OUTPUT: DC+; DC-.

Output Voltage Range

Setting error: <±2%; Adjustable range: ±10%

Rated Output Current

0~16A

0~12A

0~8A

0~6A

0~5A

0~4A

0~3.5A

0~2.5A

0~1.8A

0~1.3A

Output Voltage Ripple

Vnor<0.1%Uout ;Vp-p100Hz<0.5%Uout;Vp-pmax<1%Uout

Li;Lo Regulation

Line:±0.5%;Load:±0.5%

Overall Voltage Regulation Accuracy

±1%

Rated Output Power

≈30W

≈40W

≈40W

≈40W

≈42W

≈42W

≈43W

≈43W

≈43W

≈43W

Rated Operating Efficiency

≈70%

≈75%

≈76%

≈78%

≈79%

≈79%

≈81%

≈82%

≈83%

≈86%

Rated Input Voltage

Rated voltage: AC85~265V or DC120~380V; Operating voltage: AC76~280V. Five-pin 10.0-M4 interface labeled INPUT: AC-L, AC-N, FG.

Rated Input Current

Rated current: AC360mA (AC220V) / AC720mA (AC110V), current range AC300mA~850mA

AC Input Frequency

Rated AC voltage frequency range 47~63Hz, sine wave

Inrush Current

The surge current on the power grid at the moment of power-on: the maximum value during cold start is 20A/10ms.

Input Overvoltage Protection

            Input allowable range: AC0~280V; Overvoltage protection point: AC300V±5V, power supply enters irreversible shutdown state.

Output Overload Protection

The overload protection point is approximately 105-110% of the rated output power; the overload protection is a power-limiting voltage-dropping method; the short-circuit protection is an output power-limiting method.

Output Overvoltage Protection

------

Overheat protection

The protection point is set when the casing temperature is above +85℃±3℃; the automatic recovery setting is when the casing temperature is below +65℃±3℃; the overheat protection is a voltage drop mode.

Multi-unit series/parallel operation

Multiple units of the same power supply series can be used in series.

Power supply timing parameters

Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms

Isolation voltage parameters

[Input-Output: AC1.5KV, Input-Casing: AC1.5KV, Output-Casing: AC0.5KV] 50Hz, Power-on for 1 minute: Leakage current <5mA

Operating temperature parameters

The operating temperature drift coefficient is approximately ±0.05 [%/℃]; the absolute temperature rise coefficient is approximately 0.4 [℃/W]; the absolute temperature rise of the chassis when operating at rated power is 25℃±5℃.

Environmental conditions parameters

Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption)

Cooling method

Designed for continuous operation, the unit features a 4010 fan for enhanced air cooling and temperature-controlled speed adjustment. Without fan-assisted cooling, it can provide 60% of its rated power output.

External dimensions and mounting dimensions

Specifications: L113×W70×H38mm3; Maximum size: L115×W85×H38mm3; Installation dimensions: Bottom L101×W78mm2, Side L78×W0mm2

Net weight and color

Total weight 260g; bottom shell is 1.5mm thick aluminum with a sandblasted black finish; top shell is 0.7mm thick iron with an electroplated black finish.

Design standards

National Standards GB-4943 and GB-9254

Note: 1) All the above test pointers were measured under the following conditions: within the rated input voltage and rated output load range, in an environment of 25℃ and 85%RH, with no wind.

2) Output DC voltage ripple test: A 30cm long, 1mm² cross-section parallel stranded wire with 0.1μF and 0.47μF capacitors connected to one end was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple (Vp-p100Hz) and the maximum peak-to-peak value of the combined ripple (Vp-pmax) were measured respectively.

3) Li voltage regulation: When the load is at its rated value, the input voltage varies within the rated range; Lo load regulation: When the input is at its rated voltage value, the load varies from zero to its rated value.

Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.

Manager Lu: 13910195796
Manager Dong: 13760359528

Email: 791351592@qq.com

          21887590@163.com

Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen