Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 4-hour, 100% full load aging and full-series functional testing. |
||||||||||
|
Features Model Parameters |
SKHD- 070-1E |
SKHD- 070-1G |
SKHD- 070-1F |
SKHD- 070-1A |
SKHD- 070-1H |
SKHD- 070-1K |
SKHD- 070-1I |
SKHD- 070-1B |
SKHD- 070-1J |
SKHD- 070-1C |
|
Rated output voltage |
DC 3.3V |
DC 5V |
DC 7.5V |
DC 10V |
DC 12V |
DC 15V |
DC 18V |
DC 24V |
DC 36V |
DC 48V |
|
Output interface location |
The seven 10.0-M4 connectors are labeled OUTPUT: DC+; DC-. |
|||||||||
|
Output voltage range |
Setting error: <±2%; Adjustable range: ±10% |
|||||||||
|
Rated output current |
0~20A |
0~14A |
0~9.5A |
0~7A |
0~6A |
0~5A |
0~4A |
0~3A |
0~2A |
0~1.5A |
|
Output voltage ripple |
Vnor<0.1%Uout ;Vp-p100Hz<0.5%Uout;Vp-pmax<1%Uout |
|||||||||
|
Li ; Lo Adjustment rate |
Line:±0.5%;Load:±0.5% |
|||||||||
|
Overall voltage regulation accuracy |
±1% |
|||||||||
|
Rated output power |
≈66W |
≈70W |
≈70W |
≈70W |
≈72W |
≈75W |
≈72W |
≈72W |
≈72W |
≈72W |
|
Rated working efficiency |
≈75% |
≈78% |
≈79% |
≈82% |
≈83% |
≈84% |
≈84% |
≈85% |
≈85% |
≈86% |
|
Rated input voltage |
Rated voltage: AC85~265V, operating voltage: AC75~280V. Interface position: Seven-position 10.0-M4 wiring port markings: INPUT: AC-L, AC-N, FG |
|||||||||
|
Rated input current |
Rated current: AC 0.40~1.3A, current range AC 0.3A~1.4A |
|||||||||
|
AC input frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|||||||||
|
Input inrush current |
The surge current to the power grid at the moment of power-on: the maximum value during cold start is 20A/10ms. |
|||||||||
|
Input overvoltage protection |
Input allowable range: AC0~280V; Overvoltage protection point: AC300V±5V, power supply enters irreversible shutdown state. |
|||||||||
|
Output overload protection |
The overload protection point is approximately 115% of the rated output power, and the protection method is power limiting and voltage reduction; the short circuit protection method is online voltage reduction, and it can automatically resume operation. |
|||||||||
|
Output overvoltage protection |
------ |
|||||||||
|
Overheat protection |
------ |
|||||||||
|
Multi-machine serial and parallel functions |
Multiple units of the same power supply series can be used in series. |
|||||||||
|
Power supply time parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|||||||||
|
Isolation voltage parameters |
[Input-Output: AC1.5KV, Input-Casing: AC1.5KV, Output-Casing: AC0.5KV] 50Hz, Power-on for 1 minute: Leakage current <5mA |
|||||||||
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.05% [℃]; the absolute temperature rise coefficient is approximately 0.3 ± 10% [℃/W]; when the operating output is at rated power, the absolute temperature rise of the machine body is 25℃ ± 5℃. |
|||||||||
|
Environmental condition parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|||||||||
|
Working heat dissipation method |
Designed for continuous operation with natural cooling (power consumption is affected by the operating environment and installation location). |
|||||||||
|
External installation dimensions |
Specifications: L130×W98×H37mm3; Maximum size: L130×W100×H38mm3; Installation size: L56×W24(33)mm2, L149×W10mm2 |
|||||||||
|
Net weight and color |
The total weight is approximately 430g; the bottom shell is made of 2mm thick aluminum with a polished and anodized silver finish; the top shell is made of 0.8mm thick iron with a nickel-plated silver finish. |
|||||||||
|
Design standards based on |
National Standards GB-4943 and GB-9254 |
|||||||||
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
||||||||||
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen