Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 8-hour, 100% full load aging and full-series functional testing. |
||
|
Features |
SKGB-200-1B |
SKGB-200-1H |
|
Rated Output Voltage |
DC 24V |
DC 12V |
|
Output Interface Location |
9-position 9.5-M4 wiring port markings: OUTPUT: V+; V- |
|
|
Output Voltage Range |
Setting error: <±3%; Adjustable range: ±15% |
|
|
Rated Output Current |
Rated value 9A, operating current range 0~10A |
Rated value 12A, operating current range 0~17A |
|
Output Voltage Ripple |
Vnor<50mV;Vp-p100Hz<120mV;Vp-pmax<240mV |
|
|
Li;Lo Regulation |
Line:±0.5%;Load:±0.5% |
|
|
Overall Voltage Regulation Accuracy |
±1% |
|
|
Rated Output Power |
200W |
|
|
Rated Operating Efficiency |
≥85% (output power is rated) |
|
|
Rated Input Voltage |
Rated voltage: AC110/220V±15%, Operating voltage: AC110/220V±30%. Interface: 9-pin 9.5-M4 interface, labeled INPUT: AC-L, AC-N, FG. |
|
|
Rated Input Current |
Rated current: AC220V: AC2.85A, current range AC0.1A~2.5A; (AC110V: AC4.85A, current range AC0.5A~5.5A) |
|
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|
|
Inrush Current |
The surge current to the power grid at the moment of power-on: the maximum value during cold start is 20A/10ms. |
|
|
Output Overvoltage Protection |
If the output voltage exceeds 120% of the rated output voltage, the power supply enters protection mode. Resetting the input voltage is required to recover. |
|
|
Output Overload Protection |
The overload protection point is approximately 120% of the rated output current, and the protection is a current-limiting and voltage-reducing method; the short-circuit protection is an online voltage-drop shutdown method, and the input needs to be reset to restore it. |
|
|
Overheat protection |
The overheat protection point is 85℃±5℃, and the protection method is online shutdown. Normal operation resumes when the overall machine temperature drops below 50℃±3℃. |
|
|
Multi-unit series/parallel operation |
Multiple power supplies of the same series are allowed to be used in series and parallel (parallel operation with uneven current distribution). |
|
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|
|
Isolation voltage parameters |
[Input-Output: AC1.5KV, Input-Casing: AC1.5KV, Output-Casing: AC0.5KV] 50Hz, Power-on for 1 minute: Leakage current <8mA |
|
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.05 [%/℃]; the absolute temperature rise coefficient is approximately 0.2 [℃/W]; when the operating output is at rated power, the absolute temperature rise of the machine body is 25℃±5℃. |
|
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: 0℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|
|
Cooling method |
Designed for continuous operation, with air cooling (power consumption may vary depending on the operating environment and installation location). |
|
|
External dimensions and mounting dimensions |
Specifications and dimensions:L215×W116×H30mm32 |
|
|
Net weight and color |
The total weight is approximately 500g; the bottom shell is made of 1.5mm thick aluminum with a polished and anodized white finish; the top shell is made of 0.8mm thick iron with a nickel-plated white finish. |
|
|
Design standards |
National Standards GB-4943 and GB-9254 |
|
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
||
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen