Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 4-hour, 100% full load aging and full-series functional testing. |
||
|
Features |
SKHD-080-1B |
SKHD-080-1H |
|
Rated Output Voltage |
DC 24V |
DC 12V |
|
Output Interface Location |
The seven 9.5-M4 connectors are labeled OUTPUT: DC+; DC-. |
|
|
Output Voltage Range |
Setting error: <±2%; Adjustable range: ±10% |
|
|
Rated Output Current |
Rated value: 3.5A; Range: 0~3.5A |
Rated value 7A Range 0~7A |
|
Output Voltage Ripple |
Vnor<50mv Vp-p100Hz<50mV;Vp-pmax<200mV |
|
|
Li;Lo Regulation |
Line:±0.5%;Load:±0.5% |
|
|
Overall Voltage Regulation Accuracy |
±1% |
|
|
Rated Output Power |
≈80W |
|
|
Rated Operating Efficiency |
≈80% (output power is rated) |
|
|
Rated Input Voltage |
Rated voltage: AC100~240V, operating voltage: AC85~264V. Interface position: Seven-position 9.5-M4 wiring port markings: INPUT: AC-L, AC-N, FG |
|
|
Rated Input Current |
Rated current: AC 0.6A (AC 220V), current range AC 0.5A~1.2A |
|
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|
|
Inrush Current |
The surge current to the power grid at the moment of power-on: the maximum value during cold start is 20A/10ms. |
|
|
Input Overvoltage Protection |
Input allowable range: AC0~280V; Overvoltage protection point: AC300V±5V, power supply enters irreversible shutdown state. |
|
|
Output Overload Protection |
The overload protection point is approximately 120%-180% of the rated output power, and the protection method is power limiting and voltage reduction; the short circuit protection method is online voltage reduction, and it can automatically resume operation. |
|
|
Output Overvoltage Protection |
------ |
|
|
Overheat protection |
------ |
|
|
Multi-unit series/parallel operation |
Multiple units of the same power supply series can be used in series. |
|
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|
|
Isolation voltage parameters |
[Input-Output: AC1.5KV, Input-Casing: AC1.5KV, Output-Casing: AC0.5KV] 50Hz, Power-on for 1 minute: Leakage current <5mA |
|
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.05% [℃]; the absolute temperature rise coefficient is approximately 0.4 ± 10% [℃/W]; when the operating output is at rated power, the absolute temperature rise of the machine body is 20℃ ± 5℃. |
|
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|
|
Cooling method |
Designed for continuous operation with natural cooling (power consumption is affected by the operating environment and installation location). |
|
|
External dimensions and mounting dimensions |
Specifications: L130×W98×H37mm3; Maximum size: L130×W100×H38mm3; Installation size: L56×W24(33)mm2, L121×W10mm2 |
|
|
Net weight and color |
The total weight is approximately 430g; the bottom shell is made of 1.2mm thick aluminum with a polished and anodized silver finish; the top shell is made of 0.8mm thick iron with a nickel-plated silver finish. |
|
|
Design standards |
National Standards GB-4943 and GB-9254 |
|
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
||
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen