Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 4-hour, 100% full load aging and full-series functional testing. |
|
|
Features |
STEA-180-1B |
|
Output Interface Location |
The seven-position 9.5-7P terminal block is labeled OUTPUT: GND, GND, +24V, +24V |
|
Rated Output Voltage |
DC:+24V |
|
Output Voltage Range |
Setting error < ±5% |
|
Rated Output Current |
Rated current 7.8 A; range 0–7.5 A. |
|
Output Voltage Ripple |
Vnor<100mv Vp_p100Hz<80mv VP-Pmax<240mv |
|
Li;Lo Regulation |
Line: ±0.5%, Load: ±3% |
|
Overall Voltage Regulation Accuracy |
±5% |
|
Rated Output Power |
180W |
|
Rated Operating Efficiency |
≈80% |
|
Rated Input Voltage |
Rated voltage: AC 220V ±15%; operating voltage: AC 220V ±30%. Interface: 7-pin terminal block (9.5 mm pitch) with markings INPUT: AC-L, AC-N, FG. |
|
Rated Input Current |
Rated current: AC 1.0A; current range: AC 0.6A–1.5A. |
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|
Inrush Current |
Inrush current surge on the power grid at the moment of energization: maximum value during cold start-up is 20 A for 10 ms. |
|
Input voltage protection |
Rated voltage 220V ±15% – interface location |
|
Output Overload Protection |
The overload protection threshold is approximately 120% of the rated output current, utilizing a constant-current/voltage-reduction protection method; short-circuit protection operates by shutting down the unit upon detecting a voltage drop, and recovery requires resetting the input. |
|
Output undervoltage protection |
The undervoltage protection threshold is approximately AC 150V ±5V, at which point the power supply enters a recoverable shutdown state (requiring an input reset); the overvoltage protection threshold is AC 300V ±5V, at which point the power supply enters a non-recoverable shutdown state. |
|
Overheat protection |
The over-temperature protection threshold is 85°C ± 5°C, utilizing an automatic shutdown mode. Normal operation resumes when the unit temperature drops below 50°C ± 3°C. |
|
Multi-unit series/parallel operation |
Allows multiple units from the same series to be connected in series. |
|
Power supply timing parameters |
Setup time ≈ 200 ms; rise time ≈ 50 ms; hold-up time ≈ 20 ms. |
|
Isolation voltage parameters |
[Input-Output: AC 1.5 kV; Input-Case: AC 1.5 kV; Output-Case: AC 0.5 kV] 50 Hz, 1-minute withstand test: leakage current < 5 mA. |
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.03%/°C; the absolute temperature rise coefficient is approximately 0.3°C/W; and at rated output power, the absolute temperature rise of the unit is 25°C ± 5°C. |
|
Environmental conditions parameters |
Storage environment: -20°C to +85°C; 10% to 95% RH. Operating environment: -10°C to +50°C; 20% to 90% RH (varies depending on usage environment and power). |
|
Cooling method |
Designed for continuous operation with natural cooling (actual power output is influenced by the operating environment and installation location). |
|
External dimensions and mounting dimensions |
Dimensions: L159 × W98 × H47 mm; Maximum dimensions: L160 × W100 × H48 mm; Mounting dimensions: L150 × W85 (33) mm, L149 × W10 mm. |
|
Net weight and color |
Total weight is approximately 500g; the bottom casing is made of 2mm-thick aluminum with a black anodized finish, while the top cover is made of 0.8mm-thick iron with a black electro-coated finish. |
|
Design standards |
National Standards GB-4943; GB-9254 |
|
Notes: 1) The above parameters are measured under the following conditions: rated input voltage and rated output load range; ambient temperature of 25°C and 85% RH; and still-air conditions. 2) Output DC voltage ripple measurement: Measured at the test point using a 30 cm long, 1 mm² cross-section twisted-pair wire bypassed with 0.1 μF and 0.47 μF capacitors; measurements cover the maximum peak-to-peak value of the 100 Hz fundamental frequency ripple (Vp-p100Hz) and the maximum peak-to-peak value of the combined ripple (Vp-pmax). 3) Line regulation (Li): Measured at rated load while the input voltage varies within the rated range; Load regulation (Lo): Measured at rated input voltage while the load varies from zero to the rated value. |
|
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen