Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 8-hour, 100% full load aging and full-series functional testing. |
|
|
Features |
SKFD-200-3HK |
|
Rated Output Voltage |
DC1( +12V) DC2(+15V) DC3(-15V) |
|
Output Interface Location |
7-pin 9.5-M4 connectors are labeled OUTPUT: DC3-, DC2+, COM, DC1+, |
|
Output Voltage Range |
Setting error: <±3%; Adjustable range: ±10% |
|
Rated Output Current |
Rated values: DC1 (10A), DC2+ (2A), DC3- (2A) |
|
Output Voltage Ripple |
Vp-pmax<150mV |
|
Li;Lo Regulation |
Line:±0.5%;Load:±0.5% |
|
Overall Voltage Regulation Accuracy |
DC1±5% DC2 DC3±10% |
|
Rated Output Power |
200W |
|
Rated Operating Efficiency |
≥78% (output power is rated value) |
|
Rated Input Voltage |
Rated voltage: 100-240VAC, Operating voltage: AC90-264V; Interface: 7-pin 9.5-M4 interface, labeled INPUT: AC-L, AC-N, FG |
|
Rated Input Current |
Rated current: AC220V: AC0.85A, current range AC0.6A~0.95A; |
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|
Inrush Current |
Inrush current surge on the power grid at the moment of energization: maximum value during cold start-up is 20 A for 10 ms. |
|
Input voltage protection |
Input allowable range: AC0~280V; Overvoltage protection point: AC300V±5V, power supply enters irreversible shutdown state. |
|
Output Overload Protection |
The overload protection point is approximately 110% of the rated output current, and the protection method is power limiting and voltage reduction; the short circuit protection method is online voltage reduction, and it can automatically resume operation. |
|
Overheat protection |
The overheat protection point is 85℃±5℃, and the protection method is online shutdown. Normal operation resumes when the overall machine temperature drops below 50℃±3℃. |
|
Multi-unit series/parallel operation |
Multiple power supplies of the same series are allowed to be used in series and parallel (parallel operation with uneven current distribution). |
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|
Isolation voltage parameters |
[Input-Output: AC1.5KV, Input-Casing: AC1.5KV, Output-Casing: AC0.5KV] 50Hz, Power-on for 1 minute: Leakage current <8mA |
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.05 [%/℃]; the absolute temperature rise coefficient is approximately 0.2 [℃/W]; when the operating output is at rated power, the absolute temperature rise of the machine body is 25℃±5℃. |
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: 0℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|
Cooling method |
Designed for continuous operation with natural cooling (power consumption is affected by the operating environment and installation location). |
|
External dimensions and mounting dimensions |
Specifications: L159×W98×H38mm³; Maximum size: L160×W100×H38mm³; Installation dimensions: L150×W85mm², L149×W10mm² |
|
Net weight and color |
The total weight is approximately 600g; the bottom shell is made of 1.5mm thick aluminum with a polished and anodized white finish; the top shell is made of 1mm thick aluminum with a polished and anodized white finish. |
|
Design standards |
National Standards GB-4943 and GB-9254 |
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
|
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen