Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 4-hour, 100% full load aging and full range of functional tests. |
||||
|
Features |
SACF-060-1H |
SACF-060-1K03 |
SACF-060-1I02 |
SACF-060-1B+ |
|
Rated Output Voltage |
DC +12V BAT +13.8V |
DC +15V BAT +18.5V |
DC +18V BAT +21.5V |
DC +24V BAT +27.6V |
|
Output Interface Location |
The six P=9.5mm terminals are labeled DC+12V, DC-; BAT+, BAT-. |
|||
|
Rated Output Current |
5A 0.5A |
3.5A 0.5A |
3.5A 0.5A |
2.5A 0.5A |
|
Load current range |
0~5A ( MAX=5A ) 0~0.5A ( MAX=0.5A ) |
0~3.5A ( MAX=3.5A ) 0~0.5A ( MAX=0.5A ) |
0~3.5A ( MAX=3.5A ) 0~0.5A ( MAX=0.5A ) |
0~2.5A ( MAX=2.5A ) 0~0.5A ( MAX=0.5A ) |
|
Output Voltage Ripple |
Vp-pmax<120 mV Vp-pmax<200mV |
|||
|
Li;Lo Regulation |
Line:±0.5%;Load:±3% Line:±1%;Load:±15% |
|||
|
Overall Voltage Regulation Accuracy |
±5% ±20% |
|||
|
Rated Output Power |
60W |
|||
|
Rated Operating Efficiency |
≥70% (output power is rated value) |
|||
|
Rated Input Voltage |
Operating voltage: AC176V-264V; Rated voltage: AC220V; Interface position: Three-position covered socket, labeled AC-L, AC-N, FG. |
|||
|
Rated Input Current |
Rated current: AC 0.6A, current range AC 0.2~1.0A |
|||
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|||
|
Inrush Current |
The inrush current to the power grid at the moment of power-on: the maximum value during cold start is 60A/10ms. |
|||
|
Output Overload Protection |
The overload protection point is approximately 120%~220% of the rated output power; the overload protection is an online power limiting and voltage reduction method; the short circuit protection is an online power limiting method. |
|||
|
UPS battery management function |
An external battery (3-6AH capacity) is required as backup power. The system automatically switches to backup power when AC power is interrupted, with a switching time of ≤50ms. When AC power is normal, the system automatically switches back to AC power and manages the battery. |
|||
|
It features float charging capability for external batteries (3~6AH), and the battery has undervoltage protection (10V±0.6V) and short-circuit protection with automatic reset when discharging to a load. The battery short-circuit protection needs to be restarted after backup power is applied. |
||||
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|||
|
Dielectric strength parameters |
Input-output: >AC1.5KV; Input-casing: >AC1.5KV; Output-casing: >AC0.5KV; Leakage current <5mA; 50Hz; 1min. |
|||
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.03 [%/℃]; the absolute temperature rise coefficient is approximately 0.50 [℃/W]; the absolute temperature rise of the chassis when operating at rated power is 25℃±5℃. |
|||
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|||
|
Cooling method |
Designed for continuous operation, with self-cooling and heat dissipation assistance. (Power consumption and lifespan are affected by differences in the usage environment and installation location.) |
|||
|
External dimensions and mounting dimensions |
Specifications: L130×W98×H37mm3; Installation dimensions: L52×W31mm2, L125×W0mm2 |
|||
|
Net weight and color |
The total weight is approximately 416g; the bottom shell is made of 1.2mm thick aluminum with a sandblasted silver finish; the top shell is made of 0.5mm thick iron with an electroplated silver finish. |
|||
|
Certification Security Specifications |
National Standard GB-4943 |
|||
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
||||
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen