Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
• Compact size and lightweight.
• High reliability and low price.
• Wide input voltage range.
• High conversion efficiency and low operating temperature rise.
• Built-in filter circuit, minimizing external radiated interference.
• Basic protection circuitry, providing good environmental adaptability.
• 4-hour, 100% full load aging and full-series functional testing.
|
|
|
|
Features |
S240S125A4 |
|
Rated Output Voltage |
DC +24V |
|
Output Interface Location |
UL16AWG-L=1.2M-DC head 5.5*2.5*10 straight male fork SJTW 2C 1.31 square millimeters |
|
Output Voltage Range |
Setting error:24V±5% |
|
Rated Output Current |
12.5A |
|
Load current range |
0~12.5A( MAX=12.5A) |
|
Output Voltage Ripple |
Vp-p100Hz<100mV;Vp-pmax<240 mV |
|
Li;Lo Regulation |
Line:±0.5%;Load:±0.5% |
|
Overall Voltage Regulation Accuracy |
±5% |
|
Rated Output Power |
300W |
|
Rated Operating Efficiency |
≈80%(Output power is rated, AC176V) |
|
Rated Input Voltage |
Input range: AC176-264V; Rated voltage: AC176-264V. Interface position: Three-pin (T-shaped) - 10A 250V - L=1.2M |
|
Rated Input Current |
Rated current: AC3.0A/AC220V), current range: AC0.05~3.0A |
|
AC Input Frequency |
Rated AC voltage frequency range 50/60Hz, sine wave |
|
Inrush Current |
The inrush current to the power grid at the moment of power-on: the maximum value during cold start is 20A/10ms. |
|
Output Overload Protection |
The overload protection point is approximately 110%~180% of the rated output power. The overload protection is an online power limiting and voltage reduction method. |
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|
Dielectric strength parameters |
Input-output: AC3KV; Leakage current <5mA; 50Hz; 1min. |
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.03 [%/℃]; the absolute temperature rise coefficient is approximately 0.50 [℃/W]; the absolute temperature rise of the chassis when operating at rated power is 30℃±5℃. |
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|
Cooling method |
Designed for continuous operation, with air cooling (power consumption may vary depending on the operating environment and installation location). |
|
External dimensions and mounting dimensions |
Specifications and dimensions: L160×W90×H65mm 3 |
|
Net weight and color |
Total weight 740 grams; black surface |
|
Certification Security Specifications |
CCC |
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind.
2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively.
3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value.
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen