Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
• Compact size and lightweight.
• High reliability and low price.
• Wide input voltage range.
• High conversion efficiency and low operating temperature rise.
• Built-in filter circuit, minimizing external radiation interference.
• Basic protection circuitry, providing good environmental adaptability.
• 4-hour, 100% full load aging and full-range functional testing.
|
Features |
SB2D-025-1HA |
S050S200A4 |
S050S300B7 |
S240S100B0 |
|
Rated Output Voltage |
DC 12V |
DC5V |
DC 5V |
DC24V |
|
Output Interface Location |
Positive inside, negative outside |
|||
|
Output Voltage Range |
±10% |
|||
|
Rated Output Current |
Rated current:2A |
Rated current:2A |
Rated current:3A |
Rated current:1A |
|
Load current range |
Current range:0-2.0A |
Current range:0-2.0A |
Current range:0-3.0A |
Current range:0-1.0A |
|
Output Voltage Ripple |
Vp-pmax<100 mV |
|||
|
Li;Lo Regulation |
Line:±10%;Load:±10% |
|||
|
Overall Voltage Regulation Accuracy |
±10% |
|||
|
Rated Output Power |
25W |
10W |
15W |
25W |
|
Rated Operating Efficiency |
Greater than 80% (output power is rated value) |
|||
|
Rated Input Voltage |
Rated voltage:AC100-240V |
|||
|
Rated Input Current |
Rated current: AC 0.45A, current range AC 0.2A~0.45A |
|||
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|||
|
Inrush Current |
The inrush current to the power grid at the moment of power-on: the maximum value during cold start is 30A/10ms. |
|||
|
Input Overvoltage Protection |
…… |
|||
|
Output Overload Protection |
The overload protection point is approximately 120-200% of the rated output power; the overload protection is an online power limiting and voltage reduction method; the short circuit protection is a Hicup method. |
|||
|
Output Overvoltage Protection |
…… |
|||
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|||
|
Isolation voltage parameters |
Input-output: AC3KV, leakage current <5mA, 50Hz, 1min. |
|||
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.02 [%/℃]; the absolute temperature rise coefficient is approximately 5.00 [℃/W] |
|||
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|||
|
Cooling method |
Continuous operation mode, with natural cooling of the machine body. |
|||
|
External dimensions and mounting dimensions |
97*44.5*28mm |
|||
|
Net weight and color |
Net weight 160g, black |
|||
|
Design standards |
GB4943,GB9254,3C,UL, CE |
|||
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind.
2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively.
3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value.
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen