Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 8-hour, 100% full load aging and full-series functional testing. |
|
|
Features |
ST6B-250-1B |
|
Rated Output Voltage |
DC 24V |
|
Output Interface Location |
The seven 9.5-M4 connectors are labeled OUTPUT: DC+; DC-. |
|
Output Voltage Range |
Setting error: <±2%; Adjustable range: ±11% |
|
Rated Output Current |
Rated value 10A, operating current range 0~11A |
|
Output Voltage Ripple |
Vnor<100mV;Vp-p100Hz<150mV;Vp-pmax<240mV |
|
Li;Lo Regulation |
Line:±0.5%;Load:±0.5% |
|
Overall Voltage Regulation Accuracy |
±3% |
|
Rated Output Power |
240W |
|
Rated Operating Efficiency |
≥80% (output power is rated) |
|
Rated Input Voltage |
Rated voltage: AC220/110V±15%, Operating voltage: AC220/110V±30%. Interface position: Seven-pin 10.0-M4 interface, labeled AC-L, AC-N, FG. |
|
Rated Input Current |
Rated current: AC220V: AC1.2A, current range AC1.0A~2.5A; (AC110V: AC2.5A, current range AC1.0A~2.6A) |
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|
Inrush Current |
The surge current to the power grid at the moment of power-on: the maximum value during cold start is 60A/10ms. |
|
Input Overvoltage Protection |
Undervoltage protection at AC150V±5V: power supply enters a recoverable (reset input) shutdown state; Overvoltage protection at AC300V±5V: power supply enters an unrecoverable shutdown state. |
|
Output Overload Protection |
The overload protection point is approximately 105% of the rated output current, and the protection is a current-limiting and voltage-reducing method. |
|
Output undervoltage protection |
-------------------- |
|
Overheat protection |
Overheat protection occurs when the casing temperature exceeds approximately 85±3℃, and the protection method is an online voltage drop shutdown. Automatic recovery occurs when the casing temperature falls below approximately 65±3℃. |
|
Multi-unit series/parallel operation |
Multiple units of the same power supply series can be used in series. |
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|
Isolation voltage parameters |
[Input-Output: AC1.5KV, Input-Casing: AC1.5KV, Output-Casing: AC0.5KV] 50Hz, Power-on for 1 minute: Leakage current <5mA |
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.03 [%/℃]; the absolute temperature rise coefficient is approximately 0.16 [℃/W]; when the operating output is at rated power, the absolute temperature rise of the machine body is 25℃±5℃. |
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|
Cooling method |
Designed for continuous operation, with fan cooling for heat dissipation (power consumption varies depending on the operating environment and installation location). |
|
External dimensions and mounting dimensions |
Specifications: L200×W99×H40mm³; Maximum size: L210×W100×H42mm³; Installation dimensions: L120×W80mm², L157×W18mm² |
|
Net weight and color |
The total weight is approximately 800g; the bottom shell is made of 2.0mm thick aluminum with a natural finish; the top shell is made of 0.8mm thick iron with an electroplated natural finish. |
|
Design standards |
National Standards GB-4943 and GB-9254 |
|
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind. 2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively. 3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value. |
|