Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!

English English

We offer a variety of power supplies for customers to choose from.

SAMM-120-1H with charging

  • Detailed Description

Detailed explanation:

• Compact size and lightweight.

• High reliability and low price.

• Wide input voltage range.

• High conversion efficiency and low operating temperature rise.

• Built-in filter circuit, minimizing external radiated interference.

• Basic protection circuitry, providing good environmental adaptability.

• 4-hour, 100% full load aging and full-series functional testing.

Features
Model
Parameters

SAMM-120-1H

Rated Output Voltage

DC +12V

BAT +13.8V

Output Interface Location

The eight-pin P=9.5mm covered terminal blocks are labeled AC-L, AC-N, DC+, DC-; BAT-, BAT+, BATSW.

Output Voltage Range

Setting error: ±0.5V

Setting error: ±0.6V;

Rated Output Current

10A

0.5A

Load current range

0.5~10A ( MAX=10A )

0.2~0.5A ( MAX=0.5A )

Output Voltage Ripple

Vp-pmax<120 mV

Vp-pmax<138 mV

Li;Lo Regulation

Line:±0.5%;Load:±0.5%

Line:±1%;Load:±15%(BAT±3%)

Overall Voltage Regulation Accuracy

±1%

±16%(BAT±4%)

Rated Output Power

120W

Rated Operating Efficiency

≥75% (output power is rated value)

Rated Input Voltage

Operating voltage: AC176V-264V; Rated voltage: AC220V; Interface position: Three-position covered socket, labeled AC-L, AC-N, FG.

Rated Input Current

Rated current: AC 0.5A, current range AC 0.5~1A

AC Input Frequency

Rated AC voltage frequency range 47~63Hz, sine wave

Inrush Current

The inrush current to the power grid at the moment of power-on: the maximum value during cold start is 60A/10ms.

Output Overload Protection

The +12V overload protection point is approximately 105%~120% of the rated output power; the overload protection is an online current-limiting and voltage-reducing method; short-circuit protection requires input reset.

UPS battery management function

An external battery (5~30AH capacity) is required as backup power. When AC power fails, the system automatically switches to backup power with a switching time of ≤50ms. When AC power is normal, it automatically switches back to AC power and manages the battery (to enable the UPS function, BAT+ and BAT.SW need to be shorted).

It has the function of float charging external batteries (5~30AH), and the battery has undervoltage protection of 10V±0.6V and short circuit protection function with automatic reset when discharging to load.

Power supply timing parameters

Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms

Dielectric strength parameters

Input-output: >AC1.5KV; Input-casing: >AC1.5KV; Output-casing: >AC0.5KV; Leakage current <5mA; 50Hz; 1min.

Operating temperature parameters

The operating temperature drift coefficient is approximately ±0.03 [%/℃]; the absolute temperature rise coefficient is approximately 0.50 [℃/W]; the absolute temperature rise of the chassis when operating at rated power is 25℃±5℃.

Environmental conditions parameters

Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption)

Cooling method

Designed for continuous operation, with self-cooling and heat dissipation assistance. (Power consumption and lifespan are affected by differences in the usage environment and installation location.)

External dimensions and mounting dimensions

Specifications: L195×W110×H50mm³; Installation dimensions: L188×W98mm², L188×W23mm²

Net weight and color

The total weight is approximately 850g; the bottom shell is made of 1.5mm thick aluminum with a sandblasted silver finish; the top shell is made of 0.8mm thick iron with an electroplated silver finish.

Certification Security Specifications

National Standard GB-4943

Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind.

2) Output DC voltage ripple test: A parallel stranded wire with a length of 30cm and a cross-section of 1mm², with 0.1μF and 0.47μF capacitors connected to one end, was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively.

3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value.

Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.

Manager Lu: 13910195796
Manager Dong: 13760359528

Email: 791351592@qq.com

          21887590@163.com

Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen