Welcome to Shenzhen Shansheng Hongqi Technology Co., Ltd.!
Detailed explanation:
|
• Compact size and lightweight. • High reliability and low price. • Wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, minimizing external radiated interference. • Basic protection circuitry, providing good environmental adaptability. • 4-hour, 100% full load aging and full range of functional tests. |
|
|
Features |
SB3D-040-1BA |
|
Rated Output Voltage |
DC +24.0V |
|
Output Interface Location |
The output is 18# AWG1C+1, 5.5*2.1 tone connector, positive inside, negative outside, cable length 1.5 m. |
|
Output Voltage Range |
Setting error: ±2% |
|
Rated Output Current |
Rated current: 1.8A; Load current range: 0~1.8A |
|
Output Voltage Ripple |
Vp-p100Hz<60mV;Vp-pmax<150 mV |
|
Li;Lo Regulation |
Line:±0.5%;Load:±2.0% |
|
Overall Voltage Regulation Accuracy |
±3% |
|
Rated Output Power |
43.2W |
|
Rated Operating Efficiency |
≥75% (output power is rated) |
|
Rated Input Voltage |
Input voltage range: AC85-265V. Interface location: Standard three-pin input socket. |
|
Rated Input Current |
Rated current: AC 0.43A, current range AC 0.35A~1.2A |
|
AC Input Frequency |
Rated AC voltage frequency range 47~63Hz, sine wave |
|
Inrush Current |
The inrush current to the power grid at the moment of power-on: the maximum value during cold start is 30A/10ms. |
|
Input Overvoltage Protection |
Input allowable range: AC0~280V; Overvoltage protection point: AC300V±5V, power supply enters irreversible shutdown state. |
|
Output Overload Protection |
The overload protection point is approximately 150-250% of the rated output power; the overload protection is an online power limiting and voltage reduction method; the short circuit protection is an online power limiting method. |
|
Multi-unit series/parallel operation |
--------- |
|
Power supply timing parameters |
Setup time ≈ 200ms; Settlement time ≈ 50ms; Hold-up time ≈ 20ms |
|
Isolation voltage parameters |
Input-output: AC 1.5 kV; Input-chassis: AC 1.5 kV, leakage current <5mA, 50Hz, 1min. |
|
Operating temperature parameters |
The operating temperature drift coefficient is approximately ±0.03 [%/℃]; the absolute temperature rise coefficient is approximately 0.7 [℃/W]; the absolute temperature rise of the chassis when operating at rated power is 25℃±5℃. |
|
Environmental conditions parameters |
Storage environment: -20℃ to +85℃; 10% to 95%RH. Operating environment: -10℃ to +50℃; 20% to 90%RH. (Varies depending on the operating environment and power consumption) |
|
Cooling method |
Continuous operation mode, with natural cooling of the machine body. |
|
External dimensions and mounting dimensions |
External dimensions: L116XW47XH32mm3, desktop placement |
|
Net weight and color |
Approximately 250g, plastic casing, black |
|
Design standards |
GB4943,GB9254,3C,UL |
Note: 1) All the above test indicators were measured under the following conditions: within the rated input voltage and rated output load range, the environment was 25℃, 85%RH, and there was no wind.
2) Output DC voltage ripple test: A 30cm long, 1mm² cross-section parallel stranded wire with 0.1μF and 0.47μF capacitors connected to one end was bypassed at the test point. The maximum peak-to-peak value of the main frequency ripple Vp-p100Hz and the maximum peak-to-peak value of the combined ripple Vp-pmax were measured respectively.
3) Li voltage regulation rate: When the load is at the rated value, the input voltage varies within the rated range; Lo load regulation rate: When the input is at the rated voltage value, the load varies from zero to the rated value.
Welcome to our company, a professional R&D enterprise specializing in switching power supplies, security access control power supplies, and other related products.
Manager Lu: 13910195796
Manager Dong: 13760359528
Email: 791351592@qq.com
21887590@163.com
Add: Building 4, Block B, Fangxing Science and Technology Park, No. 17 Baonan Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen